Parker Ultra Cover® Latex Ultrasound Probe Covers | 30-00
Category: Electromedical Contact Media
Parker Ultra Cover® Natural Latex Ultrasound Probe Covers—30-00
Parker Laboratories Ultra Cover® 30-00 is a flexible, rolled natural-latex probe cover designed to create a disposable protective barrier over compatible medical ultrasound probes and transducers.
The cover measures approximately 1.38 inches wide × 7.87 inches long (3.5 × 20 cm) and is supplied with standard-size elastic bands to help secure the cover during use. Its rolled construction allows the cover to be applied over a compatible probe in a controlled manner.
Ultra Cover is nonsterile and contains natural rubber latex. It should therefore be distinguished from Parker's latex-free, pre-gelled Eclipse probe-cover family.
Parker Ultra Cover 30-00 Specifications
| Specification | Parker Ultra Cover 30-00 |
|---|---|
| Manufacturer | Parker Laboratories |
| Manufacturer REF / MPN | 30-00 |
| Product type | Ultrasound probe cover |
| Material | Natural latex |
| Latex-free | No |
| Sterility | Nonsterile |
| Design | Rolled |
| Current published dimensions | 1.38" W × 7.87" L |
| Metric dimensions | 3.5 × 20 cm |
| Elastic securing bands | Included |
| Covers per box | 100 |
| Boxes per case | 12 |
| Covers per case | 1,200 |
| Single-use | Yes. |
| UNSPSC | 42201705 |
When Should You Choose Ultra Cover?
Ultra Cover is a practical option when a facility needs a rolled natural-latex barrier for a compatible ultrasound probe and neither a sterile cover nor a latex-free material is required by the procedure, patient, probe manufacturer, or facility protocol.
The most important selection factors are
-
probe dimensions;
-
natural-latex compatibility;
-
required sterility level;
-
whether internal ultrasound gel is desired; and
-
the ultrasound-equipment manufacturer's instructions.
Ultra Cover should not be selected solely because it is less expensive than a latex-free or sterile probe-cover system.
Ultra Cover vs. Eclipse Probe Covers
Parker's Ultra Cover and Eclipse product families serve different purchasing requirements.
| Feature | Ultra Cover 30-00 | Eclipse 38-01 / 38-03 |
|---|---|---|
| Material | Natural latex | Polyethylene |
| Latex-free | No | Yes. |
| Sterile | No | No |
| Rolled | Yes. | No |
| Internal ultrasound gel | No | Pre-gelled with Aquasonic 100 |
| Sizes | One current standard size | Standard + wider 3D/4D |
| Standard quantity | 100/box | 100/box |
| Primary selection reason | Natural-latex rolled cover | Latex-free, pre-gelled configuration |
Choose Ultra Cover when natural latex is acceptable and a simple rolled probe barrier is appropriate.
Choose Parker Eclipse Probe Covers when a latex-free, internally pre-gelled cover is preferred or when the wider Eclipse 38-03 configuration is needed for a compatible 3D/4D transducer.
Important: Ultra Cover Contains Natural Latex
Ultra Cover 30-00 is manufactured from natural latex.
It should not be used when the patient, healthcare professional, facility policy, or procedure requires a latex-free product.
For a Parker latex-free alternative, compare Eclipse 38-01 and 38-03 Probe Covers.
This latex-versus-latex-free distinction should be confirmed before ordering rather than assuming all disposable ultrasound probe covers use the same material.
Is Parker Ultra Cover Sterile?
No.
Ultra Cover 30-00 is a nonsterile, rolled probe cover.
Do not treat an individually dispensed or disposable cover as sterile unless its labeling specifically states that it has been supplied sterile.
When a procedure requires sterile products or a sterile barrier, follow the probe manufacturer's instructions and applicable facility infection-control protocol.
Does Ultra Cover Include Ultrasound Gel?
Ultra Cover is not marketed as an internally pre-gelled cover.
That is another important distinction from Parker Eclipse, which contains Aquasonic 100 gel inside the cover.
When an appropriate ultrasound coupling medium is required by the probe or procedure instructions, we carry Aquasonic 100 Ultrasound Transmission Gel in multiple dispensing configurations.
For clinical procedures requiring a specifically sterile ultrasound coupling medium, compare Sterile Aquasonic 100 Ultrasound Gel and follow the applicable clinical protocol.
Why Use a Rolled Probe Cover?
A rolled cover allows the material to be progressively unrolled over a compatible transducer rather than requiring the full length of the cover to be gathered over the probe at once.
The flexible natural-latex material conforms around compatible probe shapes, while the included elastic bands help secure the cover after placement.
The correct fit should always be confirmed for the specific probe rather than assuming universal compatibility.
What Size Is Parker 30-00?
Current product information identifies REF 30-00 at approximately:
1.38 inches wide × 7.87 inches long, or 3.5 cm × 20 cm
Box of 100 vs. Case of 1,200
| Package | Box | Case |
|---|---|---|
| Parker REF | 30-00 | 30-00 |
| Covers | 100 | 1,200 |
| Boxes | 1 | 12 |
| Best fit | Lower-volume use | Routine/high-volume use |
| Storage requirement | Lower | Higher |
| Cost per cover | Higher | Lower |
Facilities using Ultra Cover routinely can lower the effective per-cover acquisition cost by purchasing the manufacturer's 12-box case.
Ultra Cover vs. Sterile Probe Covers
“Disposable” and “sterile” are not interchangeable terms.
| Feature | Ultra Cover 30-00 | Sterile Probe-Cover System |
|---|---|---|
| Disposable | Yes. | Typically yes. |
| Sterile | No | Yes. |
| Natural latex | Yes. | Product dependent |
| Appropriate when sterility is specifically required | No | Depends on device labeling |
| Best use | Procedures compatible with nonsterile latex cover | Procedures requiring an appropriately labeled sterile barrier |
The required probe cover should be selected according to the ultrasound-probe instructions, procedure type, and facility infection-control requirements.
Frequently Asked Questions
What is Parker Ultra Cover 30-00?
Ultra Cover 30-00 is Parker Laboratories' rolled natural-latex ultrasound probe cover for compatible medical ultrasound probes and transducers.
How many probe covers are in a box?
There are 100 Ultra Cover probe covers per box.
How many are in a case?
A manufacturer case contains 12 boxes, or 1,200 covers total.
Is Ultra Cover latex-free?
No. The Parker Ultra Cover contains natural latex.
For a latex-free Parker option, compare Parker Eclipse Probe Covers.
Is Ultra Cover sterile?
No. Parker identifies 30-00 as nonsterile.
What size is the Ultra Cover?
Current Parker-related specifications identify the cover as approximately 1.38 inches × 7.87 inches / 3.5 × 20 cm.
Why do some medical-supply websites list 2 × 7.1 inches?
Some distributor databases continue to display a legacy or rounded dimension. Current Parker-associated specifications identify 30-00 as 3.5 × 20 cm.
Is ultrasound gel included inside the cover?
Ultra Cover is not sold as a pre-gelled cover.
Parker's Eclipse family is the company's pre-gelled, latex-free alternative.
Are securing bands included?
standard-size elastic bands as included with Ultra Cover 30-00.
Can Ultra Cover be reused?
No. Probe covers should be treated as single-use disposable barriers and discarded according to applicable facility procedures after use.
Does a probe cover eliminate the need to disinfect the ultrasound probe?
No. A disposable cover does not replace the cleaning, disinfection, or reprocessing requirements established by the ultrasound-probe manufacturer and applicable facility protocol.
Which Parker probe cover should I choose if the patient has a latex allergy?
Do not choose the natural-latex Ultra Cover. Consider a suitable latex-free probe cover such as Parker Eclipse when its dimensions, sterility status, and intended application meet the procedure requirements.
What is the difference between Ultra Cover and Eclipse 38-03?
Ultra Cover 30-00 is a natural-latex rolled cover.
Eclipse 38-03 is a wider, latex-free, pre-gelled cover intended to accommodate compatible larger 3D/4D endocavity probes.
Product-use notice: Parker Ultra Cover 30-00 contains natural latex and is supplied nonsterile. Confirm probe compatibility and follow the current ultrasound-equipment instructions, manufacturer labeling and facility infection-control procedures. A disposable probe cover does not replace required cleaning or disinfection of a reusable ultrasound transducer.
Completing your purchase
Take a moment to review your selection and total before payment.
Preparing your order
Please consider both preparation and transit when planning your purchase.
Standard Shipping: Handling (business days) 0–1; Transit (business days) 7–15.
Express Shipping: Handling (business days) 0–1; Transit (business days) 7–15.
View policyRequesting a refund
Contact the store with your order details so your request can be reviewed.
Please contact us for the refund processing timeframe before returning an item.
View policyDelivery arrangements
The available delivery services and charges are listed below.
Standard Shipping · United States: $0.00
Express Shipping · United States: $3.99
View policyBefore arranging a return
Speak with the store before arranging a return shipment.
United States · Return window (days after delivery): 30. Return method: By mail. Return postage: Seller pays.
View policy